The CCP-W-IS is a conventional weatherproof call point based upon the industry standard KAC world series housing, and which can be used externally in hazardous areas.
The CCP-W-IS is a conventional weatherproof call point based upon the industry standard KAC world series housing, and which can be used externally in hazardous areas.
Model YBN-R/4(IS) is a Conventional Detector Mounting Base which should be used in conjunction with the SIL2 approved range of Intrinsically Safe detectors It is supplied with square cable clamps for secure and reliable cable termination but the base does not provide line continuity during detector removal, therefore if Call Points are being used then these should be wired onto the zone first.
The DCD-1E-IS(WHT) is an Intrinsically Safe Conventional Rate of Rise Heat Detector with a 60° fixed temperature element designed for use in hazardous areas. The unit also features a remote indicator output.
Model SLR-E-IS is a Photoelectric Smoke Detector designed for use in hazardous areas which also incorporates a remote indicator output and a removable chamber for easy maintenance.
Each detector incorporates Hochiki’s unique High Performance Chamber Technology removing the need to use Ionisation detectors in the majority of applications. The High Performance Chamber has also enabled the detector threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms.
Model SLR-E-IS is a Photoelectric Smoke Detector designed for use in hazardous areas which also incorporates a remote indicator output and a removable chamber for easy maintenance.
Each detector incorporates Hochiki’s unique High Performance Chamber Technology removing the need to use Ionisation detectors in the majority of applications. The High Performance Chamber has also enabled the detector threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms.
The CHQ-AB(AMB) is an addressable loop-powered Beacon, with high-intensity LEDs and a Fresnel lens design which produces a highly visible flash. The casing exactly matches the Hochiki ESP Sensor range in shape and colour providing seamless integration. The unit can be used on the Standard ESP Base (YBN-R/3), the Base Sounder (YBO-BS), the Base Sounder Beacon (YBO-BSB) or the Short-Circuit Isolator Base (YBO-R/SCI).
Key Features:
The CHQ-AB(BLU) is an addressable loop-powered Beacon, with high-intensity LEDs and a Fresnel lens design which produces a highly visible flash. The casing exactly matches the Hochiki ESP Sensor range in shape and colour providing seamless integration. The unit can be used on the Standard ESP Base (YBN-R/3), the Base Sounder (YBO-BS) or the Base Sounder Beacon (YBO-BSB).
Key Features:
Model CHQ-MRC2(SCI) is a mains relay controller providing a single mains rated relay output for the control of such devices as dampers, extractors or plant and equipment shutdown. The monitored input can be used for local power supply fault monitoring or as a general-purpose input. The mains relay controller is also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator.
Key Features:
Model ALN-ENM is a Marine Approved Photoelectric Smoke Sensor, which is fully compatible with Hochiki’s ESP Analogue Addressable Protocol.
The ALN-ENM incorporates Hochiki’s newest High Performance Chamber Technology removing the need to use Ionisation Smoke Sensors in the majority of applications. This also allows the sensor threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms.
The ALN-ENM smoke chamber is easily removed or replaced for cleaning and utilises a unique improved baffle design which allows smoke to enter the chamber whilst keeping out ambient light.
Marine Approved Dual Relay Controller with SCI
Model CHQ-DSC2/M(SCI) is a Marine Approved Dual Sounder Controller, which has been designed to provide two sounder outputs (that can be driven separately) with full fault monitoring. The monitored input can be used for local power supply fault monitoring or as a general-purpose input. The unit utilises simple DIL switches for reliable addressing.
A back box is also available (CHQ-BACKBOX) which, when used in conjunction with the CHQDSC2/M(SCI), increases the IP rating to IP65.
Model ACC-ENM is a Multi-Sensor, which is fully compatible with Hochiki’s ESP Analogue Addressable Protocol, and incorporates a thermal element and High Performance photoelectric smoke chamber.
The ACC-ENM has three modes, which are controlled from the Control Panel, allowing either the optical element or thermal element or both elements to be active in making the fire decision. The sensor polling LEDs can be controlled via the Control Panel (pulsing/non-pulsing). The ACC-ENM smoke chamber can easily be removed or replaced for easy maintenance.
Model CHQ-SZM2/M(SCI) is a Marine Approved Single Zone Monitor designed to allow up to 6 marine approved conventional detectors to be interfaced to Hochiki’s ESP analogue addressable system. The unit also features an integral short-circuit isolator. The CHQSZM2/M(SCI) utilises simple DIL switches for reliable addressing. A back box is also available (CHQ-BACKBOX) which, when used in conjunction with the CHQ-SZM2/M(SCI), increases the IP rating to IP65. The conventional zone on the CHQ-SZM2/M(SCI) does not support any line continuity options; if Call Points are being interfaced they should be wired at the beginning of the zone.
Model HCP-WM(SCI) is a weatherproof Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol.
The unit incorporates a bi-coloured LED, which can be selected as pulsing/non-pulsing*1 for communications polling and is continuously lit when the unit is operated – in these two states the LED will show red. The LED will show amber when a short-circuit is present but will switch to red if the unit is activated. The unit operates by pressing the EN54 compliant non-frangible (plastic) element and produces a high level ESP interrupt. A built in test function initiated by the control panel ensures the integrity of the device at all times and the device can be tested by insertion of a test key in the underside of the unit.
Two terminal blocks are provided for easy connection to the loop wiring. The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable addressing. An optional glass element is also available.
The CHQ-BACKBOX is designed for installations where the CHQ “Smart-Fix” Modules (CHQ-DIM, CHQ-SZM, CHQ-DZM, CHQ-DSC, CHQ-MRC, CHQ-DRC, plus SCI versions) require mounting within a glanded enclosure. The unit features ten knock-outs suitable for cable glands and accepts the CHQ Modules directly as a lid.
The CHQ-SIM has been designed to allow a single monitored input to be connected to the ESP loop. This provides a compact, low-cost option where the installation of the larger CHQ Range of Modules might be difficult.
The CHQ-SIM features flying leads as well as a wiring terminal block for loop connection, making installation quick and easy. The unit is addressed with the TCH-B100 Hand Held Programmer utilising the on-board programming connector and a PL-3 lead.