Single gang back box mounted stand alone “dumb” short circuit isolator.
Single gang back box mounted stand alone “dumb” short circuit isolator.
The EURV-MRU 240V Mains Rated Relay Unit upgrades a standard EURV-OM-RM output module to a unit capable of switching mains voltages and higher currents. Utilising an existing module for communication, control and monitoring functions means the unit is fully compatible with all panels supporting the Eurotech loop protocol. The unit can easily be upgraded to a wireless variant by adding the 240EOL-01 end of line module and connecting to a EUW-BOM-03 wireless output module. The units are perfect for switching mains voltage to equipment such as dampers and sound systems or where higher current switching is required at lower voltages.
The conventional zone monitor connects a zone of conventional detectors to a Eurotech intelligent loop. The device has an onboard relay output driven by the control panel. The conventional zone module is designed to provide different current limits. The module detects open circuits, short circuit and monitors an external power supply. The communication loop is fully isolated from the conventional zone module and from the power supply.
The Odyssey Conventional Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces a red light in alarm.
The Odyssey Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 4 heat detectors in the Odyssey Conventional designed to suit a wide variety of operating conditions.
The Odyssey Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 4 heat detectors in the Odyssey Conventional designed to suit a wide variety of operating conditions.
The Odyssey Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 4 heat detectors in the Odyssey Conventional designed to suit a wide variety of operating conditions.
The Odyssey Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 4 heat detectors in the Odyssey Conventional designed to suit a wide variety of operating conditions.
The Odyssey Standard Base has been designed to enable detectors to be fitted without the need of force – particularly useful when fitting to suspended ceilings. All Odyssey bases have a ‘one way only’ fit. Detectors can be locked into place by a grub screw using a 1.5mm hexagonal screwdriver.
The Odyssey Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the “L1 IN” and “L1 OUT” wiring terminals. This base can only be used with compatible control equipment.
The Odyssey Sav-Wire Base is designed to allow Odyssey conventional detectors to be used in ‘Sav-Wire’ detection and alarm systems.
The Odyssey Standard Relay Base provides one set of volt-free changeover (form C) contacts that change state when the detector signals an alarm.
The Odyssey Conventional 12V Relay Base is designed for use in both fire and security systems. For fire systems a jumper on the PCB is fitted to a ‘latching’ position. For security systems the jumper is moved to another position so that the base is ‘non-latching’.
SyCall is a resettable manual call point packed with unique and innovative features. It has been designed to obtain maximum visibility, high reliability in operation and pleasant aesthetical appearance and is fully approved to EN54-11.
Six modes of operation are achievable simply by choosing the appropriate internal connection terminals at the time of installation. This solution has been adopted to address the need to stock multiple units commonly seen in many other popular types of call points on the market.
The unit is highly visible in both the alarm and non-alarm state. Front facing LED and sideways facing light tubes allow the easy discovery of an activated call point.
SyCall is a resettable manual call point packed with unique and innovative features. It has been designed to obtain maximum visibility, high reliability in operation and pleasant aesthetical appearance and is fully approved to EN54-11.
The SyCall manual call point also comes in a 2 wire (Sav-Wire) variant.
Six modes of operation are achievable simply by choosing the appropriate internal connection terminals at the time of installation. This solution has been adopted to address the need to stock multiple units commonly seen in many other popular types of call points on the market.
The unit is highly visible in both the alarm and non-alarm state. Front facing LED and sideways facing light tubes allow the easy discovery of an activated call point.
The EVTB 24Vdc sounder beacon is part of the EVTG family of products designed for use with conventional fire alarm
systems including two wire (SAV-WIRE®) and other general 24Vdc applications. The sounder function, like all EVTG products, comes as standard with 32 tones. The beacon function has been designed for maximum all-round visibility, coupled with low power consumption utilising an array of energy efficient LEDs. The sounder function features a two-stage alarm override which is activated by a third negative wire from the fire panel. Both the sounder and beacon functions are fully synchronised. The product can also be used as a beacon only which is easily selected by a DIL switch at the time of installation.
Need to talk to a member of the team?
Our support & sales team are keen and would love to help with any questions. Leave your details in the contact form and we will get back to you shortly.
18-20 Stratfield Park
Elettra Avenue
Waterlooville
PO7 7XN
United Kingdom
Speak to our Experts